{"id":13191,"date":"2024-10-11T10:19:25","date_gmt":"2024-10-11T08:19:25","guid":{"rendered":"https:\/\/calcul-electrique.com\/geen-onderdeel-van-een-categorie\/te-veel-thermische-spanning-op-de-fasegeleider\/"},"modified":"2024-12-23T14:26:55","modified_gmt":"2024-12-23T13:26:55","slug":"te-veel-thermische-spanning-op-de-fasegeleider","status":"publish","type":"post","link":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/","title":{"rendered":"Te veel thermische spanning op de fasegeleider"},"content":{"rendered":"\n<div class=\"wp-block-uagb-container uagb-block-36487dc3 alignfull uagb-is-root-container\"><div class=\"uagb-container-inner-blocks-wrap\">\n<div class=\"wp-block-uagb-container uagb-block-fd17fc7a\">\n<div class=\"wp-block-uagb-container uagb-block-9d42b2c7\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-e514becd\"><h5 class=\"uagb-heading-text\">Artikel 434.5.2 van de norm NF C 15-100 :<\/h5><\/div>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">De onderbrekingstijd van een stroom als gevolg van een kortsluiting die op enig punt in het circuit optreedt, mag niet langer zijn dan de tijd die nodig is om de temperatuur van de geleiders op de toegestane limiet te brengen.  <\/p>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Voor kortsluitingen met een duur tot 5 s kan de tijd die een kortsluitstroom nodig heeft om de geleidertemperatuur te doen stijgen van de maximaal toelaatbare temperatuur bij normaal bedrijf tot de grenswaarde, als eerste benadering worden berekend met de volgende formule :  <\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-ee321cc1\">\n<div class=\"wp-block-uagb-image uagb-block-9f9d3674 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\" alt=\"\" class=\"uag-image-4715\" width=\"208\" height=\"55\" title=\"Formule\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-6900450d\">\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Waar:  <\/p>\n\n\n\n<div class=\"wp-block-uagb-icon-list uagb-block-d5207f78\"><div class=\"uagb-icon-list__wrap\">\n<div class=\"wp-block-uagb-icon-list-child uagb-block-dfe13fbc nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>t<\/strong> is de duur in seconden<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-1b3e47de nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>S<\/strong> is de dwarsdoorsnede in mm\u00b2.<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-de63382c nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>I<\/strong> de effectieve kortsluitstroom in A is, uitgedrukt als een RMS-waarde (<strong> <sub>Ik<\/sub> <\/strong>genoemd<strong> in <\/strong>de UTE C 15-105 gids)  <\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-32f07e74 nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>k<\/strong> = factor die rekening houdt met de weerstand, de temperatuurco\u00ebffici\u00ebnt en het temperatuurstijgingsgedrag van het geleidermateriaal, evenals met de uiteindelijke begintemperaturen. Voor de meest voorkomende geleiderisolaties worden de waarden van <strong>k<\/strong> voor fasegeleiders gegeven in <strong>tabel 43A <\/strong>hieronder: <\/span><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-305e6433\">\n<div class=\"wp-block-uagb-image uagb-block-856d5001 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-none\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/10\/43A.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/10\/43A.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/10\/43A.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/10\/43A.png\" alt=\"\" class=\"uag-image-4768\" width=\"1164\" height=\"393\" title=\"43A\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-e1977720\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-ec87960b wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Notes.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Notes.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Notes.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Notes.png\" alt=\"\" class=\"uag-image-4735\" width=\"1164\" height=\"255\" title=\"Opmerkingen\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-53189495\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-8fc1ba9d\"><h5 class=\"uagb-heading-text\">In elec calc\u2122 :<\/h5><\/div>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">De toelaatbare thermische spanning van een kabel is de capaciteit om een circuitstroom te weerstaan tijdens de eliminatietijd zonder dat de isolatie beschadigd raakt.<\/p>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">De waarde van de thermische spanning wordt uitgedrukt in A\u00b2.s (I\u00b2t)<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-3f55f6ae\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-73e6c868 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-1.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-1.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-1.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-1.png\" alt=\"\" class=\"uag-image-4740\" width=\"690\" height=\"193\" title=\"Afbeelding 1\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-5c539d19\">\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Bij afwezigheid van een fabrieksreferentie stroomopwaarts van de geleider, wordt de thermische spanning op de geleider berekend als functie van de maximale kortsluitstroom waargenomen door de kabel en de openingstijd van de vermogenschakelaar: I\u00b2 x t (I in A en t in s).<\/p>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Deze waarde moet kleiner zijn dan de thermische weerstand van de kabel: k\u00b2xS\u00b2.<\/p>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Waar:  <\/p>\n\n\n\n<div class=\"wp-block-uagb-icon-list uagb-block-7676eedd\"><div class=\"uagb-icon-list__wrap\">\n<div class=\"wp-block-uagb-icon-list-child uagb-block-8d96cb3e nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>S<\/strong> is de geleider doorsnede in mm\u00b2.<\/span><\/div>\n\n\n\n<div class=\"wp-block-uagb-icon-list-child uagb-block-d707c2cb nc-justify-text\"><span class=\"uagb-icon-list__source-wrap\"><svg xmlns=\"https:\/\/www.w3.org\/2000\/svg\" viewbox=\"0 0 256 512\"><path d=\"M64 448c-8.188 0-16.38-3.125-22.62-9.375c-12.5-12.5-12.5-32.75 0-45.25L178.8 256L41.38 118.6c-12.5-12.5-12.5-32.75 0-45.25s32.75-12.5 45.25 0l160 160c12.5 12.5 12.5 32.75 0 45.25l-160 160C80.38 444.9 72.19 448 64 448z\"><\/path><\/svg><\/span><span class=\"uagb-icon-list__label\"><strong>k<\/strong> is een co\u00ebffici\u00ebnt berekend volgens appendix B van de norm NF C 15-500 en ook gegeven in de verschillende tabellen in dezelfde appendix B.<\/span><\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-8ef24d09\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-ada632fe\"><h5 class=\"uagb-heading-text\">Wat is de oplossing? Integreer een fabrikantreferentie op de stroomopwaartse stroomonderbreker: <\/h5><\/div>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Om te voorkomen dat de kabeldoorsnede te groot wordt, nemen fabrikanten in de meeste beveiligingen een begrenzingseffect op.  <\/p>\n\n\n\n<p class=\"nc-justify-text\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">De beperking wordt rechtstreeks afgelezen van een curve van de fabrikant voor de stroomopwaartse beveiliging (stroomonderbreker of zekering): <strong>de energiebeperkingscurve<\/strong>. Deze definieert de maximale thermische spanning die door de geleider wordt gedragen, in overeenstemming met de maximale kortsluitstroom die door de leiding stroomt. <\/p>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-731290fd\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-d2db6174 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Courbes-1.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Courbes-1.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Courbes-1.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Courbes-1.png\" alt=\"\" class=\"uag-image-4758\" width=\"707\" height=\"326\" title=\"Curves\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-eba35bed\">\n<div class=\"wp-block-uagb-advanced-heading uagb-block-9fc2743e\"><h5 class=\"uagb-heading-text\">Interpretatie van thermische spanningswaarden in elec calc\u2122 :  <\/h5><\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-3c2a5e2f\">\n<div class=\"wp-block-uagb-image aligncenter uagb-block-d57ad3c7 wp-block-uagb-image--layout-default wp-block-uagb-image--effect-static wp-block-uagb-image--align-center\"><figure class=\"wp-block-uagb-image__figure\"><img decoding=\"async\" srcset=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-last.png ,https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-last.png 780w, https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-last.png 360w\" sizes=\"auto, (max-width: 480px) 150px\" src=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Image-last.png\" alt=\"\" class=\"uag-image-4750\" width=\"1164\" height=\"253\" title=\"Laatste afbeelding\" loading=\"lazy\" role=\"img\"><\/figure><\/div>\n<\/div>\n\n\n\n<p class=\"nc-justify-text has-black-color has-text-color has-link-color wp-elements-e5faeeac68746e25d928b77375fe0f7c\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\"> <strong> &gt; Als<\/strong> <strong>i\u00b2t k\u00b2s\u00b2 <\/strong>, verschijnt er een thermische spanningsafwijking op de kabel.  <\/p>\n\n\n\n<p class=\"nc-justify-text has-black-color has-text-color has-link-color wp-elements-0fdeb7be0d76add223d20b872e25a484\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">Zie voor meer informatie dit artikel over <a href=\"https:\/\/calcul-electrique.com\/articles\/technique\/la-verification-des-contraintes-thermiques-dans-un-conducteur\/\">het controleren van thermische spanningen in een geleider<\/a>.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-0b867a31\">\n<p style=\"margin-top:0;margin-bottom:0\">Je kunt hieronder ook de tutorial over thermische beperkingen vinden:<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-uagb-container uagb-block-43bcf400\">\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Tutoriel de formation elec calc\u2122 : La gestion des contraintes Thermiques\" width=\"500\" height=\"281\" src=\"https:\/\/www.youtube.com\/embed\/VN7-dLoK_x0?start=1&#038;feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n<\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Artikel 434.5.2 van de norm NF C 15-100 : De onderbrekingstijd van een stroom als gevolg van een kortsluiting die op enig punt in het circuit optreedt, mag niet langer zijn dan de tijd die nodig is om de temperatuur van de geleiders op de toegestane limiet te brengen. Voor kortsluitingen met een duur tot [&hellip;]<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"wp-custom-template-publications-2","format":"standard","meta":{"_uag_custom_page_level_css":"","_swt_meta_header_display":false,"_swt_meta_footer_display":false,"_swt_meta_site_title_display":false,"_swt_meta_sticky_header":false,"_swt_meta_transparent_header":false,"footnotes":""},"categories":[207,206],"tags":[],"class_list":["post-13191","post","type-post","status-publish","format-standard","hentry","category-berekening","category-faq-elec-calc-nl"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.0 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\" \/>\n<meta property=\"og:locale\" content=\"nl_NL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique\" \/>\n<meta property=\"og:description\" content=\"Artikel 434.5.2 van de norm NF C 15-100 : De onderbrekingstijd van een stroom als gevolg van een kortsluiting die op enig punt in het circuit optreedt, mag niet langer zijn dan de tijd die nodig is om de temperatuur van de geleiders op de toegestane limiet te brengen. Voor kortsluitingen met een duur tot [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\" \/>\n<meta property=\"og:site_name\" content=\"Calcul \u00e9lectrique\" \/>\n<meta property=\"article:published_time\" content=\"2024-10-11T08:19:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-23T13:26:55+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\" \/>\n<meta name=\"author\" content=\"Lionel LABAYRADE\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Geschreven door\" \/>\n\t<meta name=\"twitter:data1\" content=\"Lionel LABAYRADE\" \/>\n\t<meta name=\"twitter:label2\" content=\"Geschatte leestijd\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\"},\"author\":{\"name\":\"Lionel LABAYRADE\",\"@id\":\"https:\/\/calcul-electrique.com\/#\/schema\/person\/e90792328034839c95d8407423abfd45\"},\"headline\":\"Te veel thermische spanning op de fasegeleider\",\"datePublished\":\"2024-10-11T08:19:25+00:00\",\"dateModified\":\"2024-12-23T13:26:55+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\"},\"wordCount\":429,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/calcul-electrique.com\/#organization\"},\"image\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\",\"articleSection\":[\"Berekening\",\"FAQ elec calc\u2122\"],\"inLanguage\":\"nl-NL\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\",\"url\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\",\"name\":\"Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique\",\"isPartOf\":{\"@id\":\"https:\/\/calcul-electrique.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\",\"datePublished\":\"2024-10-11T08:19:25+00:00\",\"dateModified\":\"2024-12-23T13:26:55+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#breadcrumb\"},\"inLanguage\":\"nl-NL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage\",\"url\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\",\"contentUrl\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Accueil\",\"item\":\"https:\/\/calcul-electrique.com\/nl\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Te veel thermische spanning op de fasegeleider\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/calcul-electrique.com\/#website\",\"url\":\"https:\/\/calcul-electrique.com\/\",\"name\":\"Calcul \u00e9lectrique\",\"description\":\"Simplifiez vos projets \u00e9lectriques avec calcul \u00e9lectrique !\",\"publisher\":{\"@id\":\"https:\/\/calcul-electrique.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/calcul-electrique.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"nl-NL\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/calcul-electrique.com\/#organization\",\"name\":\"Trace Software\",\"url\":\"https:\/\/calcul-electrique.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/calcul-electrique.com\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/12\/Trace-software-2023.png\",\"contentUrl\":\"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/12\/Trace-software-2023.png\",\"width\":1900,\"height\":350,\"caption\":\"Trace Software\"},\"image\":{\"@id\":\"https:\/\/calcul-electrique.com\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.linkedin.com\/company\/trace-software-international\/\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/calcul-electrique.com\/#\/schema\/person\/e90792328034839c95d8407423abfd45\",\"name\":\"Lionel LABAYRADE\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"nl-NL\",\"@id\":\"https:\/\/calcul-electrique.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/1dc416869dee367e0cd227aca78dc9607bcb57a7d0f58fee8398a94175128c8f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/1dc416869dee367e0cd227aca78dc9607bcb57a7d0f58fee8398a94175128c8f?s=96&d=mm&r=g\",\"caption\":\"Lionel LABAYRADE\"},\"url\":\"https:\/\/calcul-electrique.com\/nl\/author\/llabayrade\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/","og_locale":"nl_NL","og_type":"article","og_title":"Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique","og_description":"Artikel 434.5.2 van de norm NF C 15-100 : De onderbrekingstijd van een stroom als gevolg van een kortsluiting die op enig punt in het circuit optreedt, mag niet langer zijn dan de tijd die nodig is om de temperatuur van de geleiders op de toegestane limiet te brengen. Voor kortsluitingen met een duur tot [&hellip;]","og_url":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/","og_site_name":"Calcul \u00e9lectrique","article_published_time":"2024-10-11T08:19:25+00:00","article_modified_time":"2024-12-23T13:26:55+00:00","og_image":[{"url":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png","type":"","width":"","height":""}],"author":"Lionel LABAYRADE","twitter_card":"summary_large_image","twitter_misc":{"Geschreven door":"Lionel LABAYRADE","Geschatte leestijd":"2 minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#article","isPartOf":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/"},"author":{"name":"Lionel LABAYRADE","@id":"https:\/\/calcul-electrique.com\/#\/schema\/person\/e90792328034839c95d8407423abfd45"},"headline":"Te veel thermische spanning op de fasegeleider","datePublished":"2024-10-11T08:19:25+00:00","dateModified":"2024-12-23T13:26:55+00:00","mainEntityOfPage":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/"},"wordCount":429,"commentCount":0,"publisher":{"@id":"https:\/\/calcul-electrique.com\/#organization"},"image":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage"},"thumbnailUrl":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png","articleSection":["Berekening","FAQ elec calc\u2122"],"inLanguage":"nl-NL"},{"@type":"WebPage","@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/","url":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/","name":"Te veel thermische spanning op de fasegeleider - Calcul \u00e9lectrique","isPartOf":{"@id":"https:\/\/calcul-electrique.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage"},"image":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage"},"thumbnailUrl":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png","datePublished":"2024-10-11T08:19:25+00:00","dateModified":"2024-12-23T13:26:55+00:00","breadcrumb":{"@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#breadcrumb"},"inLanguage":"nl-NL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/"]}]},{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#primaryimage","url":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png","contentUrl":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/01\/Formule.png"},{"@type":"BreadcrumbList","@id":"https:\/\/calcul-electrique.com\/nl\/faq-elec-calc-nl\/te-veel-thermische-spanning-op-de-fasegeleider\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Accueil","item":"https:\/\/calcul-electrique.com\/nl\/"},{"@type":"ListItem","position":2,"name":"Te veel thermische spanning op de fasegeleider"}]},{"@type":"WebSite","@id":"https:\/\/calcul-electrique.com\/#website","url":"https:\/\/calcul-electrique.com\/","name":"Calcul \u00e9lectrique","description":"Simplifiez vos projets \u00e9lectriques avec calcul \u00e9lectrique !","publisher":{"@id":"https:\/\/calcul-electrique.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/calcul-electrique.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"nl-NL"},{"@type":"Organization","@id":"https:\/\/calcul-electrique.com\/#organization","name":"Trace Software","url":"https:\/\/calcul-electrique.com\/","logo":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/calcul-electrique.com\/#\/schema\/logo\/image\/","url":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/12\/Trace-software-2023.png","contentUrl":"https:\/\/calcul-electrique.com\/wp-content\/uploads\/2024\/12\/Trace-software-2023.png","width":1900,"height":350,"caption":"Trace Software"},"image":{"@id":"https:\/\/calcul-electrique.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/trace-software-international\/"]},{"@type":"Person","@id":"https:\/\/calcul-electrique.com\/#\/schema\/person\/e90792328034839c95d8407423abfd45","name":"Lionel LABAYRADE","image":{"@type":"ImageObject","inLanguage":"nl-NL","@id":"https:\/\/calcul-electrique.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/1dc416869dee367e0cd227aca78dc9607bcb57a7d0f58fee8398a94175128c8f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1dc416869dee367e0cd227aca78dc9607bcb57a7d0f58fee8398a94175128c8f?s=96&d=mm&r=g","caption":"Lionel LABAYRADE"},"url":"https:\/\/calcul-electrique.com\/nl\/author\/llabayrade\/"}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false},"uagb_author_info":{"display_name":"Lionel LABAYRADE","author_link":"https:\/\/calcul-electrique.com\/nl\/author\/llabayrade\/"},"uagb_comment_info":0,"uagb_excerpt":"Artikel 434.5.2 van de norm NF C 15-100 : De onderbrekingstijd van een stroom als gevolg van een kortsluiting die op enig punt in het circuit optreedt, mag niet langer zijn dan de tijd die nodig is om de temperatuur van de geleiders op de toegestane limiet te brengen. Voor kortsluitingen met een duur tot&hellip;","_links":{"self":[{"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/posts\/13191","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/comments?post=13191"}],"version-history":[{"count":2,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/posts\/13191\/revisions"}],"predecessor-version":[{"id":13193,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/posts\/13191\/revisions\/13193"}],"wp:attachment":[{"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/media?parent=13191"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/categories?post=13191"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/calcul-electrique.com\/nl\/wp-json\/wp\/v2\/tags?post=13191"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}